Brooks Automation PRI-Equipe DBM Series - SERVICE

Call for Price

In stock
SKU
SERVICE_DBMSeries

Call for a repair service quote.

Brooks Automation PRI-Equipe VAC-407-2A Robot Refurbishment - Scope of Work

Refurbishment is recommended for robots over 5 years old.

PTB Sales will perform the following:

1. Incoming Inspection

  • Attach Work Order to VAC-407-2A Robot
  • Picture taken of VAC-407-2A Configuration/Condition

2. Complete teardown and disassembly

  • Replace all arm bearings
  • Replace arm link drive bands
  • Inspect condition of top flange vacuum seal area, rework as needed
  • Replace R and T servo motors
  • Replace Harmonic Drive assemblies

3. Test

  • Run Vacuum leak testing. * If fails, Ferro Fluidic seal must be rebuilt, (not included in standard pricing above will require a re-quote)
  • Run EQT Diagnostics testing.
  • Verify sensor functions
  • Test function of circuit boards and cable/wiring, replace as needed
  • Set arm COP and retract position
  • Check axes alignment and Theta “Dead Zone”
  • 48 hour Burn-in test for repeatability.

4. Final Quality  Control Check List

  • Final Test Report attached to Robot
  • Replace Service Label
  • Protective covers installed on I/I connectors
  • Package with accordance with DOT Standards
  • Clean & bag for shipment
  • Warranty (1 Year)

Brooks Automation PRI-Equipe VAC-407-2A Robot Enhanced Repair Scope of Work

PTB Sales will perform the following:

1. Incoming Inspection

  • Attach Work Order to VAC-407-2A Robot
  • Picture taken of VAC-407-2A Configuration/Condition

2. Complete teardown and disassembly

  • Inspect any wear components such as bearings and replace as needed
  • Inspect arm link drive bands, replace as needed.
  • Inspect condition of top flange vacuum seal area, rework as needed
  • Test servo-motors current and encoder function replace as needed
  • Inspect, clean and re-lubricate Harmonic Drive assemblies, replace as needed

3. Test

  • Run Vacuum leak testing. * If fails, Ferro Fluidic seal must be rebuilt, (not included in standard pricing above will require a re-quote)
  • Run EQT Diagnostics testing.
  • Verify sensor functions
  • Test function of circuit boards and cable/wiring, replace as needed
  • Set arm COP and retract position
  • Check axes alignment and Theta “Dead Zone”
  • 48 hour Burn-in test for repeatability.

4. Final Quality  Control Check List

  • Final Test Report attached to Robot
  • Replace Service Label
  • Protective covers installed on I/I connectors
  • Package with accordance with DOT Standards
  • Clean & bag for shipment
  • Warranty (6 months)

This product has been refurbished by PTB Sales, Inc. PTB Sales is not affiliated with Brooks Automation, Inc., the Original Equipment Manufacturer. In some cases, PTB Sales uses processes and parts that are different from those used by the OEM, and the OEM expressly disclaims any warranty obligations with respect to this refurbished product.

Request an RMA Return Material Authorization