USED Advanced Energy AE MDX-10K DC Magnetron Master Active Standard Z Model 3152194-005
This unit has a standard-z output transformer and software.
Output Impedance Range
Each MDX is equipped with a built in impedance matching transformer. These tap-selectable transformers are available in high Z, standard Z or low Z configurations. With the proper transformer and tap, load impedances requiring voltages from 400 V to 1,250 V can be accommodated.
Output Regulation
The MDX can be used as a power, current or voltage source, depending on the method of output regulation selected. Since setpoint levels are stored in nonvolatile memory, they can be used in recovering from input power interruptions and to ensure repeatability from run to run.
The MDXL is DC magnetron source by rectifying a switching frequency of 17 - 31 kHz. The Sparc-le integrates into existing systems with both old and new MDX products.
Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!
200 or 208 VAC rms ± 10%, 50/60 Hz, three-phase "Y" connection; maximum ground leakage current less than 3.5 mA
Input current
200 or 208 VAC full load
Maximum current (at -10% input line voltage)
19 A
38 A
57 A
76 A
95 A
114 A
Output power
0-5000 W
0-10,000 W
0-15,000 W
0-20,000 W
0-25,000 W
0-30,000 W
Chassis per system
1
2
3
Output ripple voltage (% rms)
5
2
Output ripple frequency
50 kHz
100 kHz
Output display accuracy
Within 2% of actual output level or 0.2% of maximum rated output level, whichever is greater
Target accumulator
Target life is displayed in 1-kWl increments; the counter is updated every 4.7 ms
Methods of control
Full or restricted access, local or remote control, programmed or manual operation
Output connector
UHF type, Amphenol part number 83-822 (mate supplied) or terminal block
Output cable
RG-8U coaxial cable and/or discrete cables
Size
7" (H) x 19" (W) X 19" (D) (17.8 cm x 48.3 cm x 48.3 cm)
Weight
55 lbs (25 kg)
71 lbs (32.3 kg)
Ambient temperature
Operating
Minimum 0°C, maximum 40°C (maximum value of average over 24 hr.:35°C). If the units are enclosed in cabinets, the operator will ascertain the temperature at the place of instalation and ensure that the macimum ambient temperature is not exceeded.
Storage
Minimum -25°C, maximum 55°C
Transportation
Minimum -25°C, maximum 55°C (for short periods of up to 24 hr., the maximum is 70°C)
Coolant temperature
Air (gas) minimum 0°C, maximum 35°C
Coolant flow parameters
Contamination
Cooling air should be free of corrosive vapors and particles, conductive particles, and particles that could become conductive after exposure to moisture.
Humidity
15-85% relative humidity; no condensation or icing
Atmospheric pressure
Operating
800 mbar minimum (approx. 2,000 m above sea level)
Storage
Transportation
660 mbar minimum (approx. 3,265 m above sea level)
Maximum output current: low impedance ("Low Z")
Tap 1 / 0 to 500 V output range
12.50 A
25.00 A
37.50 A
50.00 A
62.50 A
75.00 A
Tap 2 / 0 to 640 V output range
10.00 A
20.00 A
30.00 A
40.00 A
50.00 A
60.00 A
Tap 3 / 0 to 800 V output range
7.75 A
15.50 A
23.50 A
31.00 A
38.75 A
46.50 A
Maximum output current: standard impedance ("Standard Z")